Master Box

Soundproof Box [Master Box]

Master Box

Overview

This product is a compact anechoic box delivered for noise and operating sound measurements of electronic components and small devices.
By combining a rigid steel enclosure with a high-performance internal sound absorption structure, it effectively reduces both external noise leakage and internal sound reflections.

The front features a highly airtight single swing door, ensuring excellent sound insulation while maintaining smooth operability for loading and handling of test samples.

The unit is also mounted on a vibration-isolated base frame, minimizing the influence of floor-borne vibration during acoustic measurements.

Measurement target Communication and information equipment, precision equipment, electronic components, nanotechnology related products, and environmental products.
Measurement purpose Abnormal noise detection, research and development, acoustic measurement of product performance, vibration analysis, environmental testing, etc.
Measuring equipment Standard and precision sound level meters, FFT analyzers, vibration meters, various acoustic evaluation equipment, etc.

*The soundproof box is used for research and development measurement. They will be optimized based on the user’s measurement methods and specifications.

Reference Dimensions

 

Overall external dimensions (approx.) W 900 mm × D 900 mm × H 1,000 mm (main body)
Total height including base frame Approx. H 1,300 mm

 

Isolation volume (transmission loss)/dB

Ensure first-class sound insulation effect.
The sound insulation performance of this soundproof box is unparalleled by any other company. Depending on the installation environment, the background noise inside the soundproof box can be close to 0 decibels.
By introducing our soundproof box, an advanced acoustic measurement space can be created.

Isolation volume (transmission loss)/dB
Hertz 31.5 63 125 250 500 1K 2K 4K 8K
Sound insulation (24) (34) 39 43 51 55 63 64 62
Guaranteed value
Ability value 29.1 46.2 44.9 44.7 61.8 64.1 71.7 75.6 80.1
Made by a certain company 17 20 27 35 40 45

The announced sound insulation performance

We guarantee the sound insulation performance. We use a noise signal generator, speakers, and standard or precision sound level meters to measure (transmission loss test) according to JISA1417:2000 standard, and submit the test results in the form of a “measurement result report”.

* Data in this table are approximate.

Key Features

Installation Example

Example of anechoic box+sound level meter set

Typical Applications

High Sound Insulation & Sound Absorption Anechoic Box for Small Devices

Other

*According to the job responsibilities, drawer tables, lighting, power sockets, etc. can be added.
*Please request the drawings for details.

Contact

The Magicians of Silence.

Inquiry by phone

+ 86-519-68228666

Contact Us